maintenance guide

Fault finding

Overheat

 

 

 

Insufficient

Water pressure

circulation

 

 

 

 

Bleed heat exchanger

 

 

 

Pump operation

 

 

 

CH return filter for blockages

 

 

 

Circulation around boiler (blockages)

 

 

 

ntc temperature sensors

 

 

 

 

Insufficient water

Water pressure gauge for correct pressure

(request filling)

 

 

 

 

Check for waterleaks on the entire system

 

 

 

 

CH Flow temp.

Check connections and wiring to temp

probe circuit open/

sensors

short circuit

 

 

 

CH Flow temp.

Resistance values of temp sensors

probe circuit open/

 

short circuit

 

 

 

Heating delivery

Details in maintenance guide in installation

probe problem

manual

 

 

 

 

Floor thermostat

Check terminals TA2 for presence of link

contact open

wire

 

 

 

 

EEPROM Error

Check the EEPROM connection onto the

 

pcb

 

 

Communication

Check connection and wiring onto all

error

devices, main and display pcb

 

 

Main PCB error

 

 

 

 

 

Too many (>5)

Identify reason for lockout from table and

resets in 5 minutes

check for relevant faults

 

 

 

 

No Flame detected

Insufficient working gas pressure

 

 

1st Ignition failed

Spark electrode/wiring connectors

 

 

2nd Ignition failed

Ignition electrode/wiring connectors

 

 

Flame cut-off

Spark generator/wiring connectors

 

 

 

Check flue system for correct assembly/

 

termination

 

 

 

Check earth

 

 

 

Gas valve

 

 

 

CO2 settings

 

 

 

Soft light rate

 

 

Flame detected

Ignition electrode/wiring connectors

with gas valve

 

closed

 

 

 

 

Ignition electrode wiring connection onto

 

main pcb

 

 

 

 

Flame lift

Insufficient working gas pressure

 

 

 

Check flue system for correct assembly/

 

termination

 

 

 

CO2 settings

 

 

 

 

Thermofuse open

Check wiring and connections to

 

thermofuse

 

 

 

Check integriry of main heat exchanger

 

 

 

 

Fan speed error

Check fan

 

 

 

Check wiring connections from fan to pcb

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52