Menus

Field

Description

 

 

Startup Event

Configurable field; determines when the alarm is to be

 

triggered.

 

rising — alarm is triggered when the event rate

 

rises above the threshold.

 

falling — alarm is triggered when the event rate

 

falls below the threshold.

 

rising and falling — alarm is triggered when the

 

event rate rises above or falls below the thresh-

 

old.

 

 

Threshold Value

Configurable field; sets the value that triggers the alarm.

 

 

Detected Value

Read-only field; displays the last measurement made.

 

 

Rising Event

Configurable field; displays the response to a triggered

 

rising event.

 

partitionport — partitions the target port.

 

sendtrap — sends a trap to the receiving trap

 

station.

 

partitionportANDsendtrap — partitions the tar-

 

get port and sends a trap.

 

sendtrapANDrequestpage — sends a trap and

 

sends a page to the network administrator (if the

 

trap receiving station is an AsantéView Manage-

 

ment Station).

 

partitionportANDsendtrapANDrequestpage

 

— partitions the target port, sends a trap, and

 

send a page to the network administrator (if the

 

trap receiving station is an AsantéView Manage-

 

ment Station).

 

 

Falling Event

Configurable field; displays the response to a triggered

 

falling event. Options are the same as those for a rising

 

event (see “Rising Event” above).

 

 

Sample Interval

Configurable field; sets (in seconds) the polling interval.

 

Note: The shorter this time period, the more traffic on

 

the network.

 

 

Page 5-16