Chapter 2. Hardware Setup
7.(Optional) Use Cat 5e cable to connect the KN1108v / KN1116v PON port to an SA0142 Adapter. Connect the Adapter to the PON IN port of a Power Over the Net™ unit.
Note: 1. For PN5/7, go to Device Management/OOBC/Console Port Settings of GUI, and select the Baud Rate of 38400 bps.
2.Make sure the CC Management function is disabled for both the KN and PN.
3.The PON unit shown in the example is the PN0108.
See Supported Power Over the Net™ Units, page 259, for a list of suitable units.
8.(Optional) Use Cat 5e cable to connect the KN1108v / KN1116v’s Modem port to an SA0142 Adapter. Connect the Adapter’s serial connector to the modem’s
9.(Optional) For serial connectivity, use Cat 5e cable to connect the KN1108v / KN1116v’s Serial 1 port to an SA0142 Adapter. Connect the Adapter’s serial connector to any generic serial device.
10.(Optional) For further serial connectivity, use Cat 5e cable to connect the KN1108v / KN1116v’s Serial 2 port to an SA0142 Adapter. Connect the Adapter’s serial connector to any generic serial device.
11.Ground the switch. Use the grounding wire supplied with this package to connect the switch’s grounding terminal to a suitable grounded object.
Note: Do not omit this step. Proper grounding helps to prevent damage to the unit from surges or static electricity.
12.Plug the power cord(s) supplied with your package into the switch’s power socket, and then into an AC power source.
When using a single power socket, be sure to turn on the correct power switch (see Power Switches, page 12). When using both power sockets, either of the power switches can be used to turn on the KVM switch. To enable dual power, turn on both power switches.
Note: If you are connecting the power to a UPS or an ALTUSEN PN9108/ PN0108, be sure to use the utility power cords supplied with your package instead of standard power cords.
20