S-Registers 83

S-Register values

S2 AT escape character (user-defined)

This register determines the ASCII value used for an escape sequence. The default is the + character. The escape sequence allows the modem to exit data mode and enter command mode when online. Values greater than 127 disable the escape sequence.

Range:0-255

Default:43

Units:ASCII

S3 Command line termination character (user-defined)

This register determines the ASCII values as the carriage return character. This character is used to end command lines and result codes.

Range:

0-127, ASCII decimal

Default:

13 (carriage return)

Units:

ASCII

S4 Response formatting character (user-defined)

This register determines the ASCII value used as the line feed character. The modem uses a line feed character in command mode when it responds to the computer.

Range:

0-127, ASCII decimal

Default:

10 (line feed)

Units:

ASCII