S-Registers 85

S-Register values

S7 Connection completion time-out

This register sets the time, in seconds, that the modem must wait before hanging up because the carrier is not detected. The timer is started when the modem finishes dialing (originate), or goes off-hook (answer). In originate mode, the timer is reset upon detection of an answer tone if allowed by county restriction. The timer also specifies the wait for silence time for the @ dial modifier in seconds. S7 is not associated with the W dial modifier.

Range:1-255

Default:50

Units:seconds

S8 Comma pause time

This register sets the time, in seconds, that the modem must pause when it encounters a comma (,) in the dial command string.

Range:0-65

Default:2

Units:seconds

S11 DTMF dialing speed

This register determines the dialing speed.

Range:50-150

Default:95

Units:

.001 seconds