S7 Connection completion time-out
This register sets the time, in seconds, that the modem must wait before hanging up because the carrier is not detected. The timer is started when the modem finishes dialing (originate), or goes
Range:1-255
Default:50
Units:seconds
S8 Comma pause time
This register sets the time, in seconds, that the modem must pause when it encounters a comma (,) in the dial command string.
Range:0-65
Default:2
Units:seconds
S11 DTMF dialing speed
This register determines the dialing speed.
Range:50-150
Default:95
Units: | .001 seconds |