Each AH66T provides one relay that can be programmed using the ATON configuration software to provide automated events such as lift operation, screen operation, and drapery control. Connections include COMMON, NORMALLY CLOSED and NORMALLY OPEN.

Figure 3-15: Relay Connection

If a voltage trigger is required, an external power supply can be connected to the AH66T’s relay.

The relay is rated for a maximum of 24 Volts, AC or DC and a maximum of one amp of current. Do not connect to 120 VAC or 240 VAC house line wiring!