ATON AH66T-KT Operation, Settings, Programming, Unit ID DIP Switch Settings, B1 Button Operation

Models: AH66T-KT

1 90
Download 90 pages 12.31 Kb
Page 48
Image 48
Chapter 5: Operation, Settings &

A T O N

AH66T INSTALLATION MANUAL

 

 

 

Chapter 5: Operation, Settings &

 

Programming

Unit ID DIP Switch Settings

The AH66T has a Unit ID Switch on the back panel. The Factory Default setting is Unit ID

#1. In a dual AH66T system, the MAIN chassis must be set to Unit ID# 1 and the secondary chassis must be set to Unit ID # 2.

Figure 5-1: Unit ID Switch and B1 Button

B1 Button Operation

The B1 button is used for basic functionality testing of the AH66T. After the installation is completed, pressing the B1 button will initiate a test mode. The first button press will turn all zones on to source # 1 at 50% volume level, turn on the relay, and turn on the cooling fans. Additional presses will cycle through all six analog input sources and the internal AM/FM tuner and finally turn all zones, relay and the fan off. The OLED2 will display the zone status feedback during the test mode operation.

USB Port

The USB port is used to download the system configuration information in the ATON configuration software. This includes source input leveling settings, maximum volume and zone turn-on settings, IR routing, relay programming, and tuner setup. Pre-amp outputs, zone stereo/mono configuration and serial port setup information are also configured through the USB port. “Single point” downloading to OLED2s also uses the USB port.

Connect a USB to USB-mini cable from the computer to the AH66T to download.