Installation (for qualified installers only) | 13 |
Approved Venting Configurations with a Horizontal Termination and Three 90° Elbows (all vertical)
•If using a Snorkel Termination (14” or 36”) add the snorkel height to the vertical height (snorkel terminations are used primarily for basement installations).
•The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position.
21' (max)
15 feet |
10' (min) |
0feet | 5feet | 10feet | 15feet | 20feet |
Restrictor
Position # 5
| NOTE: |
| Restrictor positions are based |
| upon lab tests. The ideal restrictor |
Restrictor | position may vary slightly, |
especially when the termination is | |
Position # 1 | near a demarkation line. |
24 ' (max)
21' (max)
15feet
10' (min)
NOTE:
5 feet |
0 feet |
Horizontal sections require a 1/4"
rise every 12" of travel.
0feet | 5feet | 10feet | 15feet |
This is a horizontal elbow -
5 feet
0 feet
20feet | '(max) |
| 24 |
These are
vertical elbows.
NOT ALLOWED FOR THIS
VENT CONFIGURATION
Travis Industries | 4 1 2 2 1 0 4 | 9 3 5 0 8 1 1 7 |