Avalon Stoves Cedar EF manual Safety Label, Minimum Clearances to Combustibles, Dec.0398

Models: Cedar EF

1 42
Download 42 pages 24.55 Kb
Page 31
Image 31

Safety Label

29

The listing label is shown below for your records. It can be found inside the left side panel.

Cedar DVS FS

Report No. 028-S-38-5

Listed Vented

Gas Fireplace Heater

Tested and certified by OMNI-Test Laboratories, Inc. to the combustion performance and construction requirements of ANSI Z21.88b-1999, and applicable sections of UL 307b.

The Cedar is equipped from the factory only for use with Natural Gas. For conversion to LP (Propane) use kit supplied by the manufacturer. This appliance must be installed in accordance with all local codes, if any; if not, in USA follow ANSI Z223.1-1992 and NFPA 54(88). Installation in Manufactured or Mobile Homes must conform with: In USA, Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280. This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner’s manual for details. This appliance is not convertible for use with other gases, unless a certified kit supplied by the manufacturer is used. See owner’s manual for information on making these changes. This appliance uses a millivolt- type control system consisting of a gas control valve/regulator, a standing pilot burner assembly, a thermopile, a thermocouple, a piezo ignitor, and the ON/OFF switch. THIS UNIT DOES NOT REQUIRE 110 VOLT POWER TO OPERATE. All exhaust gases must be vented outside the structure of the living-area. Combustion air is drawn from outside the living-area structure.

This appliance is a Vented Gas Fireplace Heater. Not for use with Solid Fuel.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.

Installation and repair should be performed by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required where excessive lint from material like carpeting and bedding is present. The control compartment, the burner compartment and all circulating air passageways of the appliance must be kept clean and clear at all times.

This appliance must be properly connected to a venting system in accordance with the manufacturer’s installation instructions. This vented gas fireplace heater is not for use with air filters.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid flesh burns or clothing ignition. Young children should be carefully supervised at all times when they are in the same room as the appliance.

CAUTION:Hot while in operation. Do not touch. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away.

CAUTION:Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service person.

Use direct vent systems listed in owner’s manual to vent this appliance to the exterior.

Minimum Clearances to Combustibles

Unit to Sidewall

10” / 255mm

Alcove Min. Height

60” / 1520mm

 

Unit to Backwall

5” / 125mm

Alcove Max. Depth

48” / 1220mm

 

Unit to Cornerwall

5” / 125mm

Alcove Min Width

42.5” / 1080mm

 

Front of Unit

36” / 910mm

 

 

 

 

 

 

 

 

 

 

FAN TYPE VENTED CIRCULATOR

 

 

 

 

Blower Electrical Rating: 115V., 1.5 Amps, 60 Hz, 150 Watts

 

 

 

 

 

 

 

 

 

 

 

L.P.

N.G.

 

 

L.P.

N.G.

Input Rate on “HI” (BTU/Hr) . . .

. . . . 31,000

31,000

Minimum Inlet Pressure (inches W.C.)

. . . . . . . .

11.5”

5.5”

Input Rate on “LO” (BTU/Hr) . .

. . . . 18,500

23,276

Maximum Inlet Pressure (inches W.C.)

. . . . . . . .

13”

7”

 

 

 

Manifold Pressure on “HI” (inches W.C.)

11”

3.5”

In USA, this appliance is equipped for installation from 0-2000 ft. (0-610 m). For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed. See owner’s manual for information on making these changes.

Manufacture Date:

2000

2001

2002

Jan.

Feb.

Mar.

Apr.

May

Jun.

Jul.

Aug.

Sep.

Oct.

Nov.

10850 117th Pl. N.E. Kirkland, WA 98033

Dec.0398

Travis Industries

4 1 2 2 1 0 4

9 3 5 0 8 1 1 7

Page 31
Image 31
Avalon Stoves Cedar EF manual Safety Label, Minimum Clearances to Combustibles, Dec.0398