Safety Label | 29 |
The listing label is shown below for your records. It can be found inside the left side panel.
Cedar DVS FS
Report No.
Listed Vented
Gas Fireplace Heater
Tested and certified by
The Cedar is equipped from the factory only for use with Natural Gas. For conversion to LP (Propane) use kit supplied by the manufacturer. This appliance must be installed in accordance with all local codes, if any; if not, in USA follow ANSI
This appliance is a Vented Gas Fireplace Heater. Not for use with Solid Fuel.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.
Installation and repair should be performed by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required where excessive lint from material like carpeting and bedding is present. The control compartment, the burner compartment and all circulating air passageways of the appliance must be kept clean and clear at all times.
This appliance must be properly connected to a venting system in accordance with the manufacturer’s installation instructions. This vented gas fireplace heater is not for use with air filters.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid flesh burns or clothing ignition. Young children should be carefully supervised at all times when they are in the same room as the appliance.
CAUTION:Hot while in operation. Do not touch. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away.
CAUTION:Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service person.
Use direct vent systems listed in owner’s manual to vent this appliance to the exterior.
Minimum Clearances to Combustibles
Unit to Sidewall | 10” / 255mm | Alcove Min. Height | 60” / 1520mm |
| ||
Unit to Backwall | 5” / 125mm | Alcove Max. Depth | 48” / 1220mm |
| ||
Unit to Cornerwall | 5” / 125mm | Alcove Min Width | 42.5” / 1080mm |
| ||
Front of Unit | 36” / 910mm |
|
|
|
| |
|
|
|
|
| ||
| FAN TYPE VENTED CIRCULATOR |
|
|
| ||
| Blower Electrical Rating: 115V., 1.5 Amps, 60 Hz, 150 Watts |
|
|
| ||
|
|
|
|
|
|
|
| L.P. | N.G. |
|
| L.P. | N.G. |
Input Rate on “HI” (BTU/Hr) . . . | . . . . 31,000 | 31,000 | Minimum Inlet Pressure (inches W.C.) | . . . . . . . . | 11.5” | 5.5” |
Input Rate on “LO” (BTU/Hr) . . | . . . . 18,500 | 23,276 | Maximum Inlet Pressure (inches W.C.) | . . . . . . . . | 13” | 7” |
|
|
| Manifold Pressure on “HI” (inches W.C.) | 11” | 3.5” |