Avalon Stoves DVL Insert EF II Minimum Clearances, Installation for qualified installers only

Models: DVL Insert EF II

1 44
Download 44 pages 39.44 Kb
Page 10
Image 10
Clearances

10

Installation (for qualified installers only)

Clearances

Due to the high temperature of the heater, it should be located out of traffic and away from furniture and draperies.

Side Wall

 

Combustible

or

Non-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustible

Mantel

 

Combustible

Top

 

 

 

 

 

Facing

k

n

 

 

 

 

 

 

 

 

 

Non-

 

Combustible

m

Facing

 

l

x

Minimum Clearances

k

Sidewall to Insert

4"

l

Side Facing

4"

m

Top Facing*

35-1/2"**

n

Mantel*

35-1/2"**

x

Extension onto Hearth

1-1/4"

*The non-combustible top facing must extend 35-1/2” above the base of the insert or to the bottom of the mantel (whichever is less).

**Measured from the base of the insert.

Mantel Clearances

The maximum mantel depth is 12”.

NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.

Maximum Mantel Depth

0” 1” 2” 3” 4” 5” 6” 7” 8” 9” 10”11” 12”

 

37+”

 

36”

Mantel Height

35”

34”

Above Base of Insert (n)

33”

 

 

32”

 

31”

© Travis Industries

4080123

100-01174_002

Page 10
Image 10
Avalon Stoves DVL Insert EF II owner manual Minimum Clearances, Installation for qualified installers only