Avalon Stoves DVL Insert EF II Installation for qualified installers only, Vent Restrictor

Models: DVL Insert EF II

1 44
Download 44 pages 39.44 Kb
Page 14
Image 14
Vent Restrictor

14

Installation (for qualified installers only)

Vent Restrictor

WARNING: Restrictor adjustment should only be done by a qualified installer.

Only those installations determined to be over-drafting require this adjustment. The best indication of over-drafting is a hyper-active flame pattern (flames that move too quickly). If the air shutter is constricted, the flames become short and yellow, yet still very active. Over-drafting may affect the pilot, but this is not the best way to determine over-drafting. Over-drafting is most likely in tall venting configurations (especially if using an “Exhaust Only Re-Line”). Do not over-restrict the vent (this leads to ghosting or lifting flames - reduce restrictor setting).

To Access the Restrictor:

WARNING: Use a glove to protect

Remove the face.

your hand from burns.

 

To Adjust the Restrictor:

1 Determine a restrictor position. Start low (move the restrictor a maximum two positions at a time) and thoroughly test the heater before adjusting further.

2 Lift up the adjustment plate and move it so the correct notch falls into the slot on the adjustment bracket.

 

#3 #4

#5

 

Adjustment

#2

 

 

#1

 

 

Plate

 

 

 

Adjustment

 

 

 

Bracket

 

 

 

This restrictor is in position 1

To adjust, lift up on the

This restrictor is in

(factory setting).

adjustment plate and push it back

position 2.

 

(use pliers if necessary).

 

Vent Installation

Exhaust (4”)

Inlet (3”)

4” dia. Gas Liner

 

 

 

 

 

 

 

 

Termination Cap

 

 

 

 

 

 

3” dia. Gas Liner

 

 

 

 

 

(Simpson Part # 991)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6-5/8” to 3” & 4” Co- Linear Adapter

(Travis Part # 98900124)

Vent InstallationManual backgroundInlet Exhaust

Use hose-clamps to secure the vent.

Alternative Method: use high-temperature silicone and secure with screws.

Use hose-clamps to secure the vent.

Alternative Method: use high-temperature silicone and secure with screws.

© Travis Industries

4080123

100-01174_002

Page 14
Image 14