Avalon Stoves DVL Insert EF II Finalizing the Installation, Fine Tuning The Ember-Fyreburner

Models: DVL Insert EF II

1 44
Download 44 pages 39.44 Kb
Page 25
Image 25
FINE TUNING THE EMBER-FYRE™ BURNER

Finalizing the Installation

25

FINE TUNING THE EMBER-FYRE™ BURNER

Each installation is affected by altitude, vent configuration, and fuel quality. Because of this, the restrictor and air shutter may need to be fine tuned to each installation. Follow the hints below to fine- tune the burner for optimum performance and aesthetics.

Restrictor Adjustment:

Only those installations determined to be over-drafting require this adjustment. See the instructions on page 14 for details.

Air Shutter Hints:

For more glow, open the air shutter, however, this will make the flames more blue.

For yellow flames, close the air shutter, however, this may create less glow.

Correct

Lifting Flames

Ghosting Flames

Flickering Flames

 

Burner Ports

 

 

Burner

(holes)

 

 

The flames should burn right off the top of the burner ports (if they are too blue, adjust the air control).

Lifting flames indicate insufficient draft (restrictor is set too high).

Ghosting flames indicate

Flickering, short flames

insufficient air (restrictor set too

indicate excessive draft

high, air shutter shut down, or

(move air shutter to a higher

other venting error).

position).

Warning: If the vent configuration is installed incorrectly the vent may cause the flames inside the heater to lift or “ghost” – a dangerous situation. Inspect the flames after installation to insure proper performance. If the vent configuration is correct, yet the flames are lifting or ghosting, shut off gas to the heater and contact the dealer for information on remedying the problem.

8.Replace the glass.

9.Attach the face following the directions included with the face.

NOTE: If using the Classic Arched, Artisan, Metropolitan or Victorian Lace Face you must use the face mounting brackets included with the heater (SKU 225-20054). See page 11 for details.

10.Turn the flame adjust knob to its highest position - the flames should not contact the top of the firebox. Check the flame on low position. The flames should burn off of each burner hole. If the heater does not work correctly, contact your dealer for a remedy.

New Brackets

Old Brackets

11. Give this manual to the home owner and fully explain the operation of this heater.

© Travis Industries

4080123

100-01174_002

Page 25
Image 25
Avalon Stoves DVL Insert EF II owner manual Finalizing the Installation, Fine Tuning The Ember-Fyreburner, 4080123