41

 

CHAPTER

CCM Appliance Commands

 

 

 

 

 

5

 

 

Connect Command

The Connect command establishes a connection from the CCM console management appliance console port to a device attached to another port on that CCM appliance. To use this command, you must have previously issued a Server CLI command with the Connect=On parameter. For more information, see Connecting to Serial Devices on page 12.

Access right: port-specific

Access level: ADMIN, APPLIANCEADMIN or others with access to port

Syntax

CONNECT <port>

Table 5.1: Connect Command Parameter

ParameterDescription

<port>

Port number in the range 1-48.

 

 

Example

The following command establishes a connection from the serial console port to port 6.

> connect 6

Disconnect Command

The Disconnect command terminates a session with a serial device that was previously initiated with a Connect command. This command frees the serial port and allows other users to access it.

Access right: port-specific

Access level: ADMIN, APPLIANCEADMIN or others with access to port

Syntax

DISCONNECT