AXIS 241QA/AXIS 241SA - Event configuration 39

Event configuration

This section describes how to configure the AXIS 241QA/AXIS 241SA for alarm handling. Various actions can be configured to run when certain types of events occur.

Event type

A set of parameters describing how and when the video server is to perform certain actions

 

 

 

Triggered Event (see page 40)

the circumstances that start an event

at a signal from an external device, such as a door

 

switch or a motion sensor

 

 

 

 

 

Scheduled Event (see page 41)

the circumstances that start an event

at a pre-programmed time

 

 

 

Action

what occurs when the event runs

video images uploaded to an FTP server, email notifica-

 

tion sent.

 

 

 

 

 

Event servers

Event Servers are used for receiving uploaded image files and/or notification messages. To set up an Event server for your AXIS 241QA/AXIS 241SA, click on Event Servers under Event Config and enter the required information according to the selected server type.

Server type

Purpose

Information required

 

 

 

 

 

 

FTP Server

receives uploaded images

Descriptive name of your choice

 

 

 

• User Name and Password

 

 

 

• Upload path, (e.g. images/)

 

 

 

Port number

 

 

 

 

• Use passive mode if there is a firewall between the video

 

 

 

 

server and FTP server

 

 

 

• Use a temporary file if your FTP server does not allow an

 

 

 

 

existing file to be overwritten by a new file with the same

 

 

 

 

name.

 

 

 

 

 

 

HTTP Server

receives notification messages

Descriptive name of your choice

 

receives uploaded images

URL

 

 

 

 

• User Name and Password

 

 

 

• Proxy address/Proxy port (if required)

 

 

 

• Proxy User Name and Password (if required)

 

 

 

 

 

TCP Server

receives notification messages

Descriptive name of your choice

 

 

 

Port number

 

 

 

 

 

For details on each setting, please refer to the online help

available from each web

page.

 

 

 

 

 

Note: The images in pre-trigger and post-trigger buffers will be lost if the connection to the event server fails.

When the setup is complete, the connection can be tested by clicking the Test button (the test takes approximately 10 seconds).