Safety Precautions

AC Power Supply

Ensure the source voltage matches the voltage of the product before energizing the equipment. It is highly suggested that the AGM300 be placed on a separate circuit (with UPS or surge protection).

A switch or circuit-breaker shall be included in the building installation

It shall be in close proximity to the equipment and within easy reach of the operator

It shall be marked as the disconnecting device for the equipment

Protective Grounding

Under no circumstances should this equipment be operated without connection to a protective ground. Doing so poses a potential shock hazard and is also a violation of electrical safety standards applicable to this type of equipment.

Explosive Atmosphere

Do not operate this equipment in the presence of flammable liquids, vapors or aerosols. Operation of any electrical instrument in such an environment constitutes a safety hazard.

Proper Exhaust Venting

It is imperative that the exhaust port on this instrument be properly vented as described in this manual. Failure to do so constitutes a safety hazard.

Working Inside the Instrument

Extreme care should be exercised when accessing the interior of this instrument. Only qualified electrical maintenance personnel should perform connections and adjustments. Always de-energize the power supply before working inside the instrument.

Modifications to the Instrument

Under no circumstances should this instrument be modified without written consent from Bacharach, Inc. Changes or modifications to this instrument, not expressly approved, will void the warranty.

In Case of Malfunction

Do not continue to use this equipment if there are any symptoms of malfunction or failure. In the case of such occurrence, de-energize the power supply and contact a qualified repair technician or the nearest Bacharach Service Center. ONLY provided knockouts are to be used for electrical and communication wiring. Drilling into the box will void the warranty.

Fusing

AGM300, 120 VAC Input, Power Supply P/N 3015-3167

F1: 0.5 A, 250V Fast Acting, 5mm x 20mm, P/N 604-2538

F2: 250 mA, 250V Fast Acting, 5mm x 20mm, P/N 604-2537

F3: 5 A, 250V Fast Acting, 5mm x 20mm, P/N 604-2539

F4: 63 mA, 250V Fast Acting, 5mm x 20mm, P/N 604-2535

AGM300, 230 VAC Input, Power Supply P/N 3015-3161

F1: 250 mA, 250V Fast Acting, 5mm x 20mm, P/N 604-2537

F2: 125 mA, 250V Fast Acting, 5mm x 20mm, P/N 604-2536

F3: 5 A, 250V Fast Acting, 5mm x 20mm, P/N 604-2539

F4: 32 mA, 250V Fast Acting, 5mm x 20mm, P/N 604-2534

ADM800

F1 & F2: 1 A, 250VAC, Fast Acting, 5mm x 20mm, P/N 3015-4011

Instruction 3015-4275

iii

Page 5
Image 5
Bacharach AGM300, ADM800 manual Safety Precautions

AGM300, ADM800 specifications

The Bacharach ADM 800 and AGM 300 are advanced analyzers designed for efficient monitoring and detection of gases in various applications. Known for their reliability and accuracy, these instruments cater to commercial and industrial sectors, ensuring safety and compliance with environmental regulations.

The Bacharach ADM 800 is a portable gas detection device renowned for its ability to detect multiple refrigerants. With a user-friendly interface, it features a high-resolution display that provides real-time data on refrigerant concentrations, allowing technicians to quickly identify leaks during maintenance operations. One of its standout technologies is a highly sensitive thermal conductivity sensor, which enables the ADM 800 to differentiate between various hydrocarbon refrigerants with precision.

Equipped with data logging capabilities, the ADM 800 can store and retrieve measurement data, making it an invaluable tool for tracking refrigerant trends over time. The device supports USB connectivity for easy transfer of data to computers, facilitating detailed reporting and analysis. Its robust design incorporates a protective casing that ensures durability in challenging work environments, making it ideal for both field use and stationary applications.

On the other hand, the Bacharach AGM 300 is specifically crafted for continuous gas monitoring in HVAC systems. This stationary device excels in measuring concentrations of gases such as CO, CO2, and various refrigerants, ensuring optimal performance and compliance. The AGM 300 uses advanced electrochemical sensors for precise gas measurements, providing real-time feedback and alerting users to any hazardous conditions.

One of the notable features of the AGM 300 is its ability to integrate seamlessly with building management systems, enabling centralized control and monitoring of gas levels across multiple locations. This connectivity enhances the safety of industrial and commercial spaces by allowing for automated responses to detected gas levels, which can significantly mitigate risks associated with gas leaks.

Both models emphasize user-centric design, with intuitive interfaces and clear displays, making them accessible even to those with minimal training. Additionally, their low maintenance requirements and long sensor life contribute to reduced operational costs.

In conclusion, the Bacharach ADM 800 and AGM 300 are exemplary solutions for gas detection and monitoring. Their advanced technologies, robust features, and user-friendly designs make them indispensable for ensuring safety and regulatory compliance in various environments.