-11= TROUBLESHOOTING

-11= TROUBLESHOOTING

11-1NO AC OUTPUT

11-1-1CHECKING STATOR

1)Remove control panel and disconnect couplers on wiring.

2)Measuretheresistancebetween terminals on stator leads.

Refer toTable 9-1 (page 28) for normal re- sistance.

[Remedy]

If stator is defective, replace withnew one.

Fig. 11-1

11-1-2CHECKING CONDENSER

w If an instrument (Q.C.-meter or C-meter) for measuring capacity of condenser is available, check the capacity of condenser.

NORMAL CAPACITYOF CONDENSER

1OpF

w If you do not. have such an instrument, you can check condenser by replacing with new one and test running.

If the generator perform normally withnewcondenser, the cause of trouble is defect in original condenser.

11-1-3CHECKING ROTOR

1)Remove rear cover and stator.