10. ViewScape Configuration
10.2.3.1Using predefined timings for digital or analog output
How to select
1. Click on the drop down box. (image 10-7)
2. Select the correspondingsetting.
The following settings are possible
- SVGA
-XGA
- SXGA
- SXGA+
-UXGA
3. Make your choice between manual selected refresh rate(50 or 60 Hz) and lock to input (only the inputs
of the master can be selected).
Image 10-7
Selecting a preset timing
10.2.3.2Using the advanced timing settings for digital or analog output
How to select
1. Select first a predefined setting,see "Using predefined timings for digital or analog output", page 86.
2. Click on .
The timings menu expands. (image 10-8)
Different timing settingsare available for:
Analog output Sync generator and display interfacetimings are available
Digital output Only sync generator timings are available
3. Click on next to Sync Generator.
The Sync Generator timing window reveals. (image 10-9)
For more explanationsee "Timings of Sync Generator for Digital or Analog output", page 88.
4. Click on next Display Interface.
The Display Interface timingswindow reveals. (image 10-10)
For more explanationsee "Timings of Sync Generator for Digital or Analog output", page 88
5. Check Frame Rate Conversion when you are working with CRTprojectors.
When checked, it generates a continuous sync withdelay.
This Frame Rate Conversion option exclude the Lock on HSync.
6. Check Lock on HSync in all other cases, especially when working with moving images.
When checked, it generates discontinuedsync with minimal delay. It avoids shaking images.
This Lock on HSync option exclude the Frame Rate Conversion.
7. Horizontal sync polaritycan be positive or negative. Theposition depends on the display.
86 R5976476 VIEWSCAPE TOOLSET 01/07/2004