Barco R9040100 Random Access Adjustment Mode, Read AMDS, Options, leading edge, trailing edge

Models: R9040111 R9040101 R9040100 R9040110

1 82
Download 82 pages 3.45 Kb
Page 41
Image 41
Read AMDS

Random Access Adjustment Mode

If the value for "Horizontal Total Pixels" is wrong, sampling mistakes (small vertical bars in the projected image) will be seen in the image. Select "Total" and adjust the pixel quantity. Adjust for zero bars (hint: if the number of bars increase, adjust in the other direction).

The "Active Pixels" : determine the width of the window on the screen. This value is normally given in the source specifications. If not, adjust until full image is displayed (no missing pixels).

"Horizontal Start" : number of pixels between the beginning of the input signal and the start of the video information in the signal.

"Horizontal Period" : already filled in with the correct value when active file. (see caution above).

The "Vertical Total Lines" are already filled when an active file is selected to be edited (see caution above).

The "Active Lines" : number of horizontal lines determining the height of the projected image. This value is normally given in the specification of the source. If not, adjust until full image height is displayed (no missing lines)

Vertical start : number of lines between the start of the input signal and start of the image on the screen.

Interlaced [On] or [Off] : this selection is automatically filled when active file has to be edited. If the image is wrong due to mismeasurement, use the ENTER key to toggle between [On] and [Off]. (for interlaced images, 1 frame contains 2 fields).

Read AMDS

AMDS = automatic mode detection & synchronisation

During the installation of a file with LOAD, the system automatically measured the horizontal period, the total vertical lines and the interlaced mode.

When selecting Read AMDS, the system remeasures the above indicated items.

Options

 

 

EDIT FILE OPTIONS

Source number

1

Clamp

position

[leading]

Clamp delay

0

Clamp width

10

Field

polarity

[pos]

Field

select

[both]

Vertical

refresh

[sync]

Vertical

sync polarity

[leading]

Select with or <ENTER> to toggle

or to change value <EXIT> to return

Source Number : The source number of a non-active source can be changed to any other source number. This makes it possible to create a file for future source numbers.

Clamp Position : Clamping determines the black level of the signal.

The clamp pulse can be related to the leading or the trailing edge of the sync pulse. Use the ENTER key to toggle between [leading] and [trailing].

Clamp Delay : The time between the leading edge of the clamp pulse and the locked edge of the sync pulse. Can be any value between 0 and 255. Change the value by pushing the cursor key or .

Clamp Width : The width of the clamp pulse

Can be any value between 0 and 255. Change the value by pushing the cursor key or .

Example for clamp position [trailing]

leading edge

trailing edge

Sync pulse

Clamp pulse

Clamp

width

Clamp delay

5976135 BARCOREALITY SIM6 21032000

 

7-5

 

Page 41