9 SERVICE MODE

Service Mode

Start Up

Push the cursor key or to highlight 'Service' and then pressENTER.

Some items in the Service mode are password protected (when the password function is active). Enter the password to continue. All other password protected items are now available if you stay in the adjustment mode.

ADJUSTMENT MODE

Select a path from below :

RANDOM ACCESS

INSTALLATION

SERVICE

Select with or

then <ENTER> <EXIT> to return.

menu 1

SERVICE

IDENTIFICATION

CHANGE PASSWORD CHANGE LANGUAGE CHANGE PROJ. ADDRESS CHANGE BAUDRATE PC RESET LAMP RUNTIME LAMP RUNTIME HISTORY DIMMING

COMMON ADDRESS : 0

MORE...

Select with or

then <ENTER> <EXIT> to return.

SERVICE

BARCO LOGO

PANEL ADJUSTMENTS

UNIFORMITY

RESET INPUT BALANCE

I2C DIAGNOSIS

MORE...

Select with or

then <ENTER> <EXIT> to return.

menu 2

menu 3

Built-up of the service mode.

The service menu is built-up in two parts which are connected together with the 'more' item.

If the desired item is not in the list of the displayed menu, select 'more' with the cursor key and pushENTER to display the other items in the service menu.

SERVICE

IDENTIFICATION

CHANGE PASSWORD CHANGE LANGUAGE CHANGE PROJ. ADDRESS CHANGE BAUDRATE PC RESET LAMP RUNTIME LAMP RUNTIME HISTORY DIMMING

COMMON ADDRESS : 0

MORE...

Select with or

then <ENTER> <EXIT> to return.

SERVICE

IDENTIFICATION

TITLE PAGE

SIM OPTIONS

Select with or

then <ENTER> <EXIT> to return.

CHANGE PASSWORD

Enter new password

0000

Select with or

then <ENTER> <EXIT> to return.

CHANGE LANGUAGE

ENGLISH

Select with or

then <ENTER> <EXIT> to return.

BARCO LOGO

PANEL ADJUSTMENTS

UNIFORMITY

PRESET INPUT BALANCE

I2C DIAGNOSIS

MORE...

Select with or

then <ENTER> <EXIT> to return.

CHANGE PROJ. ADDRESS

Projector address : 1

Common address (RC5) : 0

Common address (PPM) : 0

Select with or

then <ENTER> <EXIT> to return.

CHANGE BAUDRATE PC

230400

115200

57600

38400

19200

9600

4800

1200

Select with or <ENTER> to accept <EXIT> to return.

RESET LAMP RUN TIME

Enter the

serial number

of the new lamp

0000000

Select with or

Reprogram with or

or numeric keys

<ENTER> to confirm

<EXIT> to return

LAMP RUNTIME HISTORY

DIMMING

Serial No Runtime

-----------------------------------------------------

> 0111121

600 h

0110031

990 h

0110010

1000 h

0000000

0 h

0000000

0 h

0000000

0 h

0000000

0 h

-----------------------------------------------------

<EXIT> to return