2. Basic Commands
Command
Command [0] \x26
Command [1] \x02
Returned Data
Data [0] = minimum Brightness value
Example
Reads the minimum Brightness value of the projector, the awnser being \x00
Transm it
Start \xfe
Projector address \x01
Command[0] \x26
Command[1] \x02
Checksum \x29
Stop \xff
Receive (acknowledge)
Start \xfe
Projector address \x01
Command[0] \x00
Command[1] \x06
Checksum \x07
Stop \xff
Receive (Answer)
Start \xfe
Projector address \x01
Command[0] \x26
Command[1] \x02
Data [0] \x00
Checksum \x29
Stop \xff
2.7.12 Maximum Brightness, Read
Description
Reads the Maximum (range) Brightness value of the projector
Command
Command [0] \x27
Command [1] \x02
28 R5976884 RLM SERIES 04/04/2006