2. Basic Commands
Returned Data
Data [0] = minimum Gamma value
Example
Reads the minimum Gamma value of the projector, the awnser being \x10
Transm it
Start \xfe
Projector address \x01
Command[0] \x26
Command[1] \x70
Checksum \x97
Stop \xff
Receive (acknowledge)
Start \xfe
Projector address \x01
Command[0] \x00
Command[1] \x06
Checksum \x07
Stop \xff
Receive (Answer)
Start \xfe
Projector address \x01
Command[0] \x26
Command[1] \x70
Data [0] \x10
Checksum \xa7
Stop \xff
2.7.30 Maximum Gamma, Read
Description
Reads the Maximum (range) Gamma value of the projector
Command
Command [0] \x27
Command [1] \x70
Returned Data
Data [0] = Maximum Gamma value
Example
Reads the Maximum Gamma value of the projector, the awnser being \x1c
40 R5976884 RLM SERIES 04/04/2006