3. Advanced Commands
byte value:
0 = OFF; 1 = ON
Example
Enables the Automatic startup
Transm it
Start \xfe
Projector address \x01
Command[0] \x20
Command[1] \x96
Data[0] \x01
Checksum \xb8
Stop \xff
Receive (acknowledge)
Start \xfe
Projector address \x01
Command[0] \x00
Command[1] \x06
Checksum \x07
Stop \xff
3.14 Automatic startup, Read
Description
Reads whether the Automatic startup is enabled or not
Command
Command [0] \x21
Command [1] \x96
Returned Data
Data [0] = unsigned byte
byte value:
\x00 =OFF;\x01 =ON
Example
Reads the Automatic startup, being \x00 =OFF
124 R5976884 RLM SERIES 04/04/2006