3. Advanced Commands
Receive (acknowledge)
Start \xfe
Projector address \x01
Command[0] \x00
Command[1] \x06
Checksum \x07
Stop \xff
Receive (Awnser)
Start \xfe
Projector address \x01
Command[0] \x21
Command[1] \x86
Data [0] \x10
Data [1] \x00
Checksum \xb8
Stop \xff
3.18 AutoImage setup, Write
Description
Sets up the AutoImage i.e. selects the AutoImage parameters.
Command
Command [0] \x20
Command [1] \x90
Data
Unsigned word.see chapter "1. Serial communications Basics", "Data words", page 6
Data[0] = unsigned byte (msb)
Data[1] = unsigned byte (lsb)
Parameter Data[0] Data[1] Hex Value
Tota l Pix e l s 0000 0001 \x01
Contrast/Brightness 0000 0010 \x02
Phase 0000 0100 \x04
Start pixel/line 0000 1000 \x08
Totalpixels + cont/bright 0000 0011 \x03
...
Example
Set up AutoImage for “TotalPixels”
132 R5976884 RLM SERIES 04/04/2006