4. Operation
Setup Menu
•Remote Control — This function sets up the PDS for remote control.
|
|
|
| |
| REMOTE CONTROL |
|
| |
| > Unit ID |
| 25 |
|
| IP | 192.168.000.002 |
|
|
| Status |
| n/a |
|
| Connect | OFF |
| |
|
|
|
|
|
Figure 4-44. Remote Control Submenu (sample)
For complete details, see “Appendix B” on page 129.
•IP — The IP line is an
Note
The PDS’s default IP address is 192.168.0.10
•M — The M line is an
pÉêá~ä=pÉíìé
From the System Menu, select Serial Setup to display the Serial Setup Menu, which enables you to set system
|
|
|
|
| SERIAL SETUP |
|
|
| > Baud | 115200 |
|
| Parameters | N81 |
|
| Handshaking | ON |
|
| Reset |
|
|
|
|
|
|
Figure 4-45. Serial Setup Menu (sample)
The following functions are available:
•Baud — Use this function to set the baud rate.
~
~
Adjustment range: 9600, 38400, 57600 and 115200
Default: 115200
•Parameters — This function is a combined setting of Parity, Data Bits and Stop bits (in this order).
~
~
Adjustment range: N81, E71, O71, E72, O72
Default: N81
•Handshaking — This is a status field for the hardware flow of the serial port.
~Default: OFF (the only valid value)
By default, RTS/CTS and DSR/DTR are ignored.
•Reset — Use this function to reset all serial values to their default settings.