4. Operation

Setup Menu

Remote Control — This function sets up the PDS for remote control.

 

 

 

 

 

REMOTE CONTROL

 

 

 

> Unit ID

 

25

 

 

IP

192.168.000.002

 

 

 

Status

 

n/a

 

 

Connect

OFF

 

 

 

 

 

 

Figure 4-44.Remote Control Submenu (sample)

For complete details, see “Appendix B” on page 129.

IP — The IP line is an information-only line that shows the current IP address in all modes (with DHCP on or off). If an IP address has not been established (no DHCP server found, or the network cable is not connected), the address reads "000.000.000.000."

Note

The PDS’s default IP address is 192.168.0.10

M — The M line is an information-only line that shows the MAC (hardware) address of the unit's Ethernet port.

pÉêá~ä=pÉíìé

From the System Menu, select Serial Setup to display the Serial Setup Menu, which enables you to set system RS-232 parameters for the serial port.

 

 

 

 

 

SERIAL SETUP

 

 

 

> Baud

115200

 

 

Parameters

N81

 

 

Handshaking

ON

 

 

Reset

 

 

 

 

 

 

Figure 4-45.Serial Setup Menu (sample)

The following functions are available:

Baud — Use this function to set the baud rate.

~

~

Adjustment range: 9600, 38400, 57600 and 115200

Default: 115200

Parameters — This function is a combined setting of Parity, Data Bits and Stop bits (in this order).

~

~

Adjustment range: N81, E71, O71, E72, O72

Default: N81

Handshaking — This is a status field for the hardware flow of the serial port.

~Default: OFF (the only valid value)

By default, RTS/CTS and DSR/DTR are ignored.

Reset — Use this function to reset all serial values to their default settings.

68

 

PDS • User’s Guide

 

Page 84
Image 84