Belkin PRO2 user manual BANK DIP Switch Configuration Chart, I N Sta L L At I O N

Models: PRO2

1 37
Download 37 pages 59.87 Kb
Page 15
Image 15
BANK DIP Switch Configuration Chart

I N STA L L AT I O N

BANK DIP Switch Configuration Chart

 

 

DIP SWITCH#

 

 

BANK ADDRESS

1

2

3

4

5

6

 

ON

ON

ON

ON

ON

ON

BANK 00 MASTER (default)

ON

ON

OFF

ON

ON

ON

BANK 01 SLAVE

ON

ON

ON

OFF

ON

ON

BANK 02 SLAVE

ON

ON

OFF

OFF

ON

ON

BANK 03 SLAVE

ON

ON

ON

ON

OFF

ON

BANK 04 SLAVE

ON

ON

OFF

ON

OFF

ON

BANK 05 SLAVE

ON

ON

ON

OFF

OFF

ON

BANK 06 SLAVE

ON

ON

OFF

OFF

OFF

ON

BANK 07 SLAVE

ON

ON

ON

ON

ON

OFF

BANK 08 SLAVE

ON

ON

OFF

ON

ON

OFF

BANK 09 SLAVE

ON

ON

ON

OFF

ON

OFF

BANK 10 SLAVE

ON

ON

OFF

OFF

ON

OFF

BANK 11 SLAVE

ON

ON

ON

ON

OFF

OFF

BANK 12 SLAVE

ON

ON

OFF

ON

OFF

OFF

BANK 13 SLAVE

ON

ON

ON

OFF

OFF

OFF

BANK 14 SLAVE

ON

ON

OFF

OFF

OFF

OFF

BANK 15 SLAVE

Note: “On” is the down position.

Example:

Four 8-Port PRO2s (F1DA108T) are daisy-chained together for controlling up to 32 computers. The DIP switch on the Master unit is set to “BANK 00” (factory default) and the Slave units are each set to a unique BANK (between 01 and 15).

13

Page 15
Image 15
Belkin PRO2 user manual BANK DIP Switch Configuration Chart, I N Sta L L At I O N