THE PUMP MOTOR WILL NOT RUN

 

Possible Causes

What To Do

 

 

 

 

 

The connection of the power cord to the power

Make sure the power cord is fully plugged in to a

 

source is faulty.

proper power source.

 

 

 

 

 

 

The circuit breaker has been tripped.

1.

Disconnect from power.

 

 

2.

Open electrical enclosure.

 

 

3.

Reset circuit breaker.

 

 

4.

Close electrical enclosure.

 

 

 

 

 

 

THE FILL HOSE IS LEAKING

 

 

 

 

 

 

 

 

Possible Causes

What To Do

 

 

 

 

Fill hose is leaking at the connection.

Hose bracket needs adjusting or tightening.

 

 

 

 

Fill hose is leaking near the pump.

Check for missing or damaged o-ring.

 

 

 

 

 