Situation |
| Possible Solutions |
| |
|
|
|
| |
IR camera image is not displayed after the | Wait two minutes after the Bendix® XVision® Night Vision Sys- | |||
Bendix logo fades away on the display. | tem has been powered to view the IR camera image. | |||
|
|
|
| |
| Check to see if the IR camera window is blocked. | |||
|
|
|
| |
| Headlamps were turned off and the XVision system timed out | |||
| (approximately 7 seconds after the headlamps are turned off | |||
| the display will turn off.) |
| ||
|
|
|
| |
| Check to see if the IR camera is aimed correctly. | |||
|
|
|
| |
Display image is upside down. | Check that DIP switch 4 is set correctly. Reference figure 14 on | |||
| page 8. |
|
|
|
|
|
|
| |
Display image is reversed, right to left. | Check that DIP switch 3 is set correctly. Reference figure 14 on | |||
| page 8. |
|
|
|
|
|
|
| |
The display image is difficult to view. | Check to see if the display intensity is set correctly. | |||
|
|
|
| |
| Check that the combiner is open to an angle that allows you to | |||
| see the image. |
|
|
|
|
|
|
| |
| Check to see if the combiner, fold mirror, and LCD are clean. | |||
|
|
|
| |
| Check to see if the IR camera window is cracked. Moisture | |||
| between the window and lens will limit image quality. | |||
|
|
|
| |
Snow build up on the IR camera window with the | Check the | |||
Bendix® XVision® Night Vision System powered. | the IR camera heater. Reference figure 21 on page 11. | |||
|
|
|
| |
| Check that the terminals are seated and the wiring is secure. | |||
|
|
|
| |
| Check the | |||
| XVision system schematic, figure 43 on page 23 @ + | |||
|
|
|
|
|
| Description |
| Voltage | |
| A | IR camera heater |
| + 12 Volts |
|
| power |
|
|
| B | IR camera heater |
| ground |
|
| power |
|
|
Please note that this product is obsolete and parts/kits listed in this document are no longer serviceable through Bendix.