Section E: Additional Component Details
6.0SmarTire 
6.1SmarTire 
6.1.1Power, Mounting, and Environmental Requirements
●Operating voltage range 9 – 36V
●Typical current consumption (with no external loads) 30mA
●5A fuse is required between the main power line of the trailer link and the vehicle battery
●Frequency 433.92 MHz
●Modulation type: OOK
●Design protected for FSK
●500 kHz Band Width
●Sensitivity (OOK) at 433.92 MHz : 
●Internal antenna only
●Uses standard Deutsch enclosure
●Tested to SAE J1455 Specifications
●Operating temperature range: 
●Survivability temperature range: 
●Sealed to IP67
●Preferred mounting orientation to shed water is vertical (Connector side facing rear of trailer, away from driving direction)
●Preferred Mounting hardware: ¼ 
●The SmarTire 
37