7.1.4 Q: What additional diagnostic information is available?

A:The external LED part # K075866 is connected via the cable harness as a separate plug. Please refer to Section C, 4.0, step 7 for details on installation and location of this LED. The LED functions as described in the table below. Flashing with pattern will have periods of 0.3 second on and 0.3 second off repeating every 6 seconds. The number of high pulses in each 6–second window will be determined by a code. For example if the flash code is 2, the pattern will be 0.3 second on, 0.3 second off, 0.3 second on, 5.1 seconds off and repeating.

Alarms

Priority

External LED

See

 

 

 

Note

No Alarms

0

Off

-

Second Level Low Pressure (SAL)

6

Pattern flashing

-

 

 

code: 4

 

SAL Cleared

0

Off

-

First Level High Pressure (FAL_H)

4

Pattern flashing

-

 

 

code: 2

 

First Level Low Pressure (FAL_L)

3

Pattern flashing

-

 

 

code: 2

 

FAL Cleared

0

Off

-

High Temperature

7

Pattern flashing

-

 

 

code: 5

 

High Temperature Cleared

0

Off

-

Sensor Diagnostic Trouble Code (DTC) Set

2

Pattern flashing

1

 

 

code: 1

 

Sensor DTC Cleared

0

Off

-

ROM To Both Copy Performed

10

Pattern flashing

2

 

 

code: 7

 

Set Up DTC

5

Pattern flashing

3

 

 

code: 3

 

Set Up DTC Cleared

0

Off

-

Factory To Custom Copy Performed

9

Pattern flashing

2

 

 

code: 7

 

Custom To Factory Copy Performed

8

Pattern flashing

4

 

 

code: 7

 

Watchdog Reset

11

Pattern flashing

5

 

 

code: 8

 

Sensor Battery Low Alert

1

Pattern flashing

-

 

 

code: 6

 