SRP-F310/312

2-2-6 Setting the Memory Switches

This printer has Memory Switch set which is software switches. Memory Switch set has MSW1, MSW2,MSW3, MSW4, MSW5, MSW6, MSW11, MSW12, Customize value.

Memory Switch setting utility can change the Memory Switch set to ON or OFF as shown in the table below (default: all OFF):

Settings of the Memory Switch are stored in the NV memory: therefore, even if the printer is turned off, the settings are maintained.

Notes: The Memory Switch is available to be changed by three methods:

-Memory Switch setting utility.

-Control from BXL/POS command.

MSW1

 

Switch

 

 

 

 

Function

 

 

ON

 

 

OFF

 

MSW 1-1

 

 

 

Select Print Speed

 

 

Refer to following Table

 

MSW 1-2

 

 

 

 

 

 

MSW 1-3

 

 

 

 

 

 

 

 

 

 

 

 

 

MSW 1-4~5

 

 

 

 

 

 

 

--

 

 

Fixed to OFF

 

MSW 1-6

 

 

 

Select Print Density

 

 

Refer to following Table

 

MSW 1-7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MSW 1-8

 

 

 

 

 

 

 

--

 

 

Fixed to OFF

 

MSW1-1~MSW1-3

 

 

 

 

 

 

 

 

 

 

MSW 1-3

 

MSW 1-2

 

MSW 1-1

 

 

 

Print speed

 

 

Remark

 

OFF

 

OFF

 

OFF

 

 

Print speed level 4

 

 

270 mm/s

 

OFF

 

OFF

 

ON

 

 

Print speed level 3

 

 

250 mm/s

 

OFF

 

ON

 

OFF

 

 

Print speed level 2

 

 

230 mm/s

 

OFF

 

ON

 

ON

 

 

Print speed level 1

 

 

200 mm/s

 

MSW1-6~MSW1-7

 

 

 

 

 

 

 

 

 

 

MSW 1-7

MSW 1-6

 

Print density

 

 

Remark

 

ON

 

OFF

 

 

 

Density level 3

 

 

Dark

 

OFF

 

ON

 

 

 

Density level 2

 

 

 

 

OFF

 

OFF

 

 

 

Density level 1

 

 

Light(Default)

 

MSW2

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

 

 

 

 

Function

 

 

ON

 

 

OFF

1

 

 

Specification for Destination

 

 

Double byte Country

 

Single byte Country

2

 

 

 

 

 

Reserved

 

--

 

 

Fixed to OFF

3~8

 

 

 

 

Code Page Selection

 

 

Refer to following Table

Rev. 1.00

- 12 -

Page 12
Image 12
BIXOLON SRP-F310/312 service manual Setting the Memory Switches, MSW1, MSW2