Status Registers

Disconnect Buffer Delay S62

The S62 register determines the delay before disconnect, to allow buff- ers to empty, when disconnect conditions exist.

Bit

Value

Command

Description

 

 

 

 

7-0

0

%D

Buffer disabled

 

1-255

%Dn

Disconnect buffer delay value (seconds)

 

 

 

 

Maximum Transmit Block Size S63

The S63 register sets the maximum transmit block size.

Bit

Value

Command

Description

 

 

 

 

7-0

63

\A

Maximum block size = 64

 

127

\A1

Maximum block size = 128

 

191

\A2

Maximum block size = 192

 

255

\A3

Maximum block size = 256

 

 

 

 

Auto-Reliable Fallback Character S64

The S64 register stores the selected ASCII value of the auto-reliable fallback character.

Bit

Value

Command

Description

 

 

 

 

7-0

0

%A

Disable auto-reliable fallback

 

 

 

character

 

1-127

%An

ASCII value 1-127

 

 

 

 

S65-66

Reserved

10-20

Modem 3600

Page 164
Image 164
Black Box 3600 Disconnect Buffer Delay S62, Maximum Transmit Block Size S63, Auto-Reliable Fallback Character S64, S65-66