Hardware Options

Factory Option Sets

Factory Option Set #1

(Asynchronous Dial-up with V.42 bis Protocol) (AT&F or AT&F1)

MODEM OPTIONS DCE rate - 33600 Modulation automode

V.34 rate threshold high

V.34 asymmetric rate enabled Normal originate

Fast train disabled Auto retrain enabled SQ auto rate disabled Transmit clock internal Dial line

Jack type RJ11

Line current disconnect long Long space disconnect enabled V.22 guard tone disabled

PROTOCOL OPTIONS LAPM protocol enabled MNP protocol enabled Protocol fallback enabled Data compression normal Constant DTE speed DTE flow control RTS DCE flow control CTS XON/XOFF pass through disabled Inactivity timer off

Break control 5

V.42 fast detect enabled

SPEAKER OPTIONS

Volume low

On until carrier detect

TEST OPTIONS

Bilateral digital loop disabled DTE local test disabled DTE remote test disabled Remote commanded test enabled Test timeout off

DIAL LINE OPTIONS Tone dial

Auto dial #1

Wait for dial tone

Wait delay 2 seconds

Pause delay 2 seconds

Call timeout 30 seconds

Answer on 1 ring

Autocallback disabled

DTE OPTIONS

Async data

DTE rate - 115200 8 bit, no parity Async controlled dialer

AT command set enabled DTR disconnects

DSR forced high DCD normal CTS forced high DTE fallback disabled

Options retained at disconnect

E-28

Modem 3600

Page 236
Image 236
Black Box Asynchronous Dial-up with V.42 bis Protocol AT&F or AT&F1, Modem Options DCE rate 33600 Modulation automode