Image 237

Hardware Options

Factory Option Set # 2

(Asynchronous Dial-up without V.42 bis Protocol) (AT&F2)

MODEM OPTIONS DCE rate - 33600 Modulation automode

V.34 rate threshold low *

V.34 asymmetric rate enabled Normal originate

Fast train disabled Auto retrain enabled SQ auto rate disabled Transmit clock internal Dial line

Jack type RJ11

Line current disconnect long Long space disconnect enabled V.22 guard tone disabled

TEST OPTIONS

Bilateral digital loop disabled DTE local test disabled DTE remote test disabled Remote commanded test enabled Test timeout off

DIAL LINE OPTIONS Tone dial

Auto dial #1

Wait for dial tone

Wait delay 2 seconds

Pause delay 2 seconds

Call timeout 30 seconds

Answer on 1 ring

Autocallback disabled

PROTOCOL OPTIONS

DTE OPTIONS

LAPM protocol disabled *

Async data

MNP protocol disabled *

DTE rate - 115200

Normal buffer mode *

8 bit, no parity

Constant DTE speed

Async controlled dialer

DTE flow control disabled *

AT command set enabled

DCE flow control disabled *

DTR disconnects

XON/XOFF pass through disabled *DSR forced high

Inactivity timer off

DCD normal

Break control 0 *

CTS forced high

V.42 fast detect disabled *

DTE fallback disabled

 

Options retained at disconnect

SPEAKER OPTIONS

Volume low

On until carrier detect

*Indicates variation from factory option set #1