Status Registers

Remote Configuration Guard Time S42

Select the remote configuration guard time (0-255) in 20 ms intervals. The default is 50 (1 sec).

S43

Reserved

XON Character from DTE S44

Select the XON character (0-127) to be sent from the DTE. The default value is ASCII 17.

XOFF Character from DTE S45

Select the XOFF character (0-127) to be sent from the DTE. The default value is ASCII 19.

S46-48

Reserved

XON Character to DTE S49

Select the XON character (0-127) to be sent to the DTE. The default value is ASCII 17.

XOFF Character to DTE S50

Select the XOFF character (0-127) to be sent to the DTE. The default value is ASCII 19.

Dial Line Transmit Level S51

The S51 register selects dial line transmit level from -9 to -30 dBm in 1 dBm increments. The default value is 10.

Bit

Value

Command

Description

 

 

 

 

4-0

0 to 30

*TDn (n=9

Transmit level in dBm (-9 through -30

 

 

to 30)

dBm)

 

 

 

 

7-5

--

--

Reserved

 

 

 

 

10-14

Modem 3600

Page 158
Image 158
Black Box 3600 Remote Configuration Guard Time S42, S43, XON Character from DTE S44, Xoff Character from DTE S45, S46-48