16
G-Converter Chassis
SALES: 0118 965 5100
10 Base-T Port (Telnet Management)
This method uses the 10 Base-T RJ45 (Ethernet) port. When a Telnet compatible PC is
connected to this port a management platform identical to that available via the Supervisor
Port is supported.
Before Telnet or SNMP management is used, it is essential that the notes relating to
Supervisor Port Management be studied. (See pages12-15).
To enable SNMP or Telnet management, information must be added to the Manager Card via
the Supervisor Port. The user must first set up various parameters namely IP address, Subnet
Mask and Gateway.
The information required is:
System Name
A text field to identify the system. May be up to 32 characters.
Location
A text field to identify the location of the system. May be up to 32 characters.
IP Address
The IP address of the system. This must be set from the supervisor port to enable SNMP or
Telnet access.
Subnet Mask
The Subnet mask of the local network. This must be set from the supervisor port before
SNMP and Telnet access is required.
Gateway
The IP address of the default gateway from the local network.
To assist the process of adding this information, the relating to Supervisor port management
is detailed below.