Black Box RMU200 manual Abandoning Changes

Models: RMU200

1 35
Download 35 pages 36 Kb
Page 29
Image 29

G-Converter Chassis

Abandoning Changes

Pressing ESC at any point before a configuration is updated will cause the message “Abandon Changes? (y/n)” to appear at the bottom of the screen. If “n” is selected the message will disappear and editing may continue. If “y” is pressed, all modifications will be abandoned and the last updated configuration will be re-printed on the screen.

Changing the Configuration Page

The Configuration Page required, e.g. “Alarms”, is selected by moving the cursor to the upper right area and pressing Enter when alongside the required page. The currently selected page is indicated by a ‘*’.

Restoring the Factory Default Configuration

The system may be reset back to the factory default configuration by pressing CTRL-Rfour times when the cursor is on the Terminal emulation page (see page 12). A ‘Confirm’ message will be displayed before the configuration is reset. The previous configuration will be lost.

This method uses the 10Base–T RJ45 port (Ethernet) port. An SNMP management package i.e. (Open View, SNMP) can be used along with the supplied MIB to manage the Card Cage System.

If additional Channel Cards are installed after the initial installation, a new MIB may be required, please contact Black Box for information

The MIB must be compiled and installed in accordance with the instructions for the specific SNMP management application being used. You should refer to the user guide for your SNMP management software for more details.

TECHNICAL: 0118 931 2233 29

Page 29
Image 29
Black Box RMU200 manual Abandoning Changes