G-Converter Chassis

Abandoning Changes

Pressing ESC at any point before a configuration is updated will cause the message “Abandon Changes? (y/n)” to appear at the bottom of the screen. If “n” is selected the message will disappear and editing may continue. If “y” is pressed, all modifications will be abandoned and the last updated configuration will be re-printed on the screen.

Changing the Configuration Page

The Configuration Page required, e.g. “Alarms”, is selected by moving the cursor to the upper right area and pressing Enter when alongside the required page. The currently selected page is indicated by a ‘*’.

Restoring the Factory Default Configuration

The system may be reset back to the factory default configuration by pressing CTRL-Rfour times when the cursor is on the Terminal emulation page (see page 12). A ‘Confirm’ message will be displayed before the configuration is reset. The previous configuration will be lost.

Telnet Screen

The Telnet screen allows Telnet specific parameters to be set.

TCP Port

TCP port being used (Read only)