Black Box RMU200 manual Abandoning Changes, Changing the Configuration

Models: RMU200

1 35
Download 35 pages 36 Kb
Page 15
Image 15

G-Converter Chassis

Abandoning Changes

Pressing ESC at any point before a configuration is updated will cause the message “Abandon Changes? (y/n)” to appear at the bottom of the screen. If “n” is selected, the message will disappear and editing may continue. If “y” is pressed, all modifications will be abandoned and the last updated configuration will be re-printed on the screen.

Changing the Configuration Page

The Configuration Page required, e.g. “Alarms”, is selected by moving the cursor to the upper right area and pressing Enter when alongside the required page. The currently selected page is indicated by a ‘*’.

Restoring the Factory Default Configuration

The system may be reset to the factory default configuration by pressing CTRL-Rfour times when the cursor is on the Terminal emulation page (see page 12). A ‘Confirm’ message will be displayed before the configuration is reset. The previous configuration will be lost.

TECHNICAL: 0118 931 2233 15

Page 15
Image 15
Black Box RMU200 manual Abandoning Changes, Changing the Configuration, Restoring the Factory Default Configuration