G-Converter Chassis

Supervisor Terminal Requirements

The terminal should be configured as follows:

8 bits per character, no parity, one stop bit, speed 19.2 Kbps.

A ‘modem’ or ‘straight’ serial cable is suitable for connection of the Supervisor port (the Supervisor port pin-out out is described in Appendix C).

Supervisor Terminal Emulation

The Manager Card supports several terminal emulations. When connection is made between the terminal and the RS232 Supervisor port, the following screen will appear:

Please select terminal type from the following:

1 = VT52

2 = VT100

3 = ADDSVP

4 = ADM3A

5 = H1500

6 = N8009

7 = TVI920

The terminal type or emulation in use should be selected by pressing the relevant number key on the PC or terminal. The terminal will then show the basic configuration screen for the chassis’s set-up.

You may return to this screen at any time by pressing ‘CTRL’ and ‘E’ at the same time.