G-Converter Chassis

Appendix C - EMC Requirements

To ensure compliance with the EMC directive, some care must be taken to ensure that the units are installed properly, using suitable screened cables and connections. The following must be observed:

This product relies on the use of screened cables for connection to the 9 Way 'D-Type' Supervisor port. The cable must have the foil or braid screen connected effectively to the metal headshell to ensure continued compliance.

The diagram below illustrates an example of a suitable screen connection. Note how the foil or braid screen is bent back over the 'C' clip to achieve a pressure contact of the screen against the shell:

It is important to keep the screen to shell connection as short as possible.

10 Base-T Supervisor Port Connections

Description

Type At Connector

RJ45 Socket

 

 

 

 

 

 

TxP

Output

1

 

 

 

TxN

Output

2

 

 

 

RxP

Input

3

 

 

 

RxN

Input

6

 

 

 