G-Converter Chassis

SNMP Management

To enable SNMP or Telnet management, information must be added to the Manager Card via the Supervisor Port. The user must first set up various parameters namely IP address, Subnet Mask and Gateway.

The information required is:

System name

A text field to identify the system. May be up to 32 characters.

Location

A text field to identify the location of the system. May be up to 32 characters.

IP Address

The IP address of the system. This must be set from the Supervisor port to enable SNMP or Telnet access.

IP Address

The Subnet mask of the local network. This must be set from the Supervisor port before SNMP and Telnet access is required.

Gateway

The IP address of the default gateway from the local network.

To assist the process of adding this information, the relating to Supervisor port management is detailed below.

Supervisor Terminal Requirements

The terminal should be configured as follows:

8 bits per character, no parity, one stop bit, speed 19.2 Kbps.

A ‘modem’ or ‘straight’ serial cable is suitable for connection of the Supervisor port (the Supervisor port pin-out out is described in Appendix C).