12.Brewer is ready to use.

SERVICING INSTRUCTIONS (continued)

7.Set the tanks back into the brewer. Reassemble the tank lid to the tanks. Make sure the gasket is properly in place, then reinstall the hold-down strap.

8.Reinstall wiring to heating elements and controller Reinstall the hi-limit thermostat (if removed). For right side, reassemble piping for the faucet. Verify that all internal components are dry, then reinstall the top panel.

10.Reconnect brewer to electrical supply and reconnect water supply.

11.Install the brew chambers without filter papers or grounds. Run at least three full brew cycles and discard all water generated.

12.Brewer is ready to use.

645 75908 Owners Manual E.B.C. Dual Airpot/Thermal Brewer

NOTE: Normally, silicone hoses do not need to be delimed. Should deliming hoses become necessary, Bloomfield recommends replacing the hoses.

21