VENTILATOR OPERATION

1.Press the VENTILATOR POWER switch to ON. The green VENTILATOR POWER light will glow and the blower fan will start. After a short time, if all filters are sensed as being in position and not clogged, the cooking appliance will be energized.

During normal operation, the VENTILATOR POWER light will be the only light glowing on the upper control panel.

2.If the amber CHECK FILTER light glows, one or more filter elements is out of position. Check the GREASE BAFFLE, PRE-FILTER and FILTER PACK for proper installation in their respective positions. Grease baffle and filter pack position are sensed by mechanical switches. Pre-filter position is sensed by a vacuum switch.

3.When the amber REPLACE PRE-FILTERlight glows, the pre-filter is nearing the end of its service life. Replace the disposable

PRE-FILTER ELEMENT.

4.When the amber REPLACE FILTER PACK light illuminates, the HEPA / Charcoal filter pack is nearing the end of its service life. Replace the FILTER PACK.

Note: The REPLACE PRE-FILTER and REPLACE FILTER PACK lights are a warning that the indicated filter is near the end of its service life. The appliance will continue to operate for a period of time after the light glows to allow continued operation through a peak period. However, the indicated filters must be replaced within a reasonably short time period or they will clog and shut down electrical power to the cooking appliance . The ventilator blower will continue to run.

5.When the red SERVICE REQUIRED light glows, either the pre-filter or filter pack (or both) is clogged and can no longer pass sufficient air to allow further operation. The ventilator fan continues to run, but the cooking appliance is shut down until the underlying clogged filter situation has been corrected. This can occur when neither CHANGE...FILTER indicator light is lit, if both pre-filter and filter pack are marginal. Replacing both the pre-filter and the filter pack will remedy the situation.

Note: Replacing the pre-filter, even though not very dirty, will often extend the service life of the more expensive filter pack.

Reset the unit by turning the VENTILATOR POWER switch to OFF, then back ON.

6.A failure of incoming electrical power will cause a shut down of the unit. After power is restored, reset the unit by turning the VENTILATOR POWER switch to OFF, then back ON.

NOTE: Oven, griddle and hotplate will not operate unless the fire suppression system is charged, and the ventilator section is operating .

OPERATION

CAUTION:

Hot Surface

Exposed surfaces can be hot to the touch and may cause burns.

Fig. 10 Ventilator Indicator and Warning Lights

13

Page 15
Image 15
Bloomfield WVOC-2HFG, WVOC-2HSG operation manual Ventilator Operation, PRE-FILTER Element, Hot Surface

WVOC-2HFG, WVOC-2HSG specifications

The Bloomfield WVOC-2HSG and WVOC-2HFG models represent the cutting edge in advanced automation and control systems designed for diverse industrial applications. These systems serve as pivotal tools for optimizing processes, enhancing efficiency, and ensuring precise monitoring of various operations across numerous sectors.

One of the main features of the Bloomfield WVOC-2HSG and WVOC-2HFG is their dual functionality, which allows for simultaneous management of multiple process parameters. The WVOC-2HSG variant is tailored for high-speed data acquisition and processing, making it suitable for environments where real-time monitoring is crucial. In contrast, the WVOC-2HFG offers enhanced flexibility with its feature-rich interface and robust control capabilities, catering to applications that demand customization and adaptability.

Both models leverage advanced technologies such as Internet of Things (IoT) connectivity, enabling seamless integration with existing infrastructure. This connectivity facilitates remote monitoring and control, allowing operators to access data from anywhere, thus improving decision-making and response times. The cloud-based analytics feature further empowers users to generate insights from historical data, leading to better predictions and proactive maintenance strategies.

In terms of characteristics, the Bloomfield WVOC-2HSG and WVOC-2HFG systems come equipped with high-resolution displays and intuitive user interfaces. These interfaces are designed to minimize the learning curve for new users while providing seasoned operators with the tools needed for complex tasks. The systems also include a variety of input and output options, making them compatible with a wide array of sensors and actuators.

Durability is another significant characteristic of these models, as they are engineered to withstand challenging industrial environments. Built with rugged materials, they are resistant to dust, moisture, and extreme temperatures, ensuring reliable performance over time.

Moreover, safety features are seamlessly integrated into these systems, with built-in alarms and redundancy mechanisms designed to prevent operational failures. This commitment to safety underscores Bloomfield's dedication to providing not only performance but also peace of mind for operators.

In conclusion, the Bloomfield WVOC-2HSG and WVOC-2HFG models stand out as premier solutions in industrial automation, showcasing a blend of innovative technology, user-centric design, and enhanced durability. Whether for real-time data processing or flexible control capabilities, these systems are set to redefine standards in operational efficiency and reliability across various industries.