SECTION 5 - HEALTH HAZARDS

 

 

 

 

ANSULEX Low pH (continued)

Threshold

None Established

 

 

 

 

Limit Value:

 

 

 

 

 

 

 

 

 

 

 

 

Routes of Entry:

Irritant

 

 

 

 

 

 

Eye Contact:

 

 

 

 

 

 

Skin Contact:

Irritant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inhalation:

Not an expected route of entry. Can be irritating to mucous membranes.

 

 

 

 

 

 

 

 

 

Ingestion:

Irritating to mucous membranes. Acute Oral LD50 (Sprague-Dawley rats) 825.5mg/kg.

 

 

 

Signs and

Acute Exposure: Material irritates skin, eyes, and mucous membranes.

 

Symptoms:

Chronic Exposure: None known.

 

 

 

Medical Conditions Generally

None known.

 

 

 

 

 

Aggravated by Exposure:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chemical Listed as

National Toxicology

Yes

I.A.R.C

Yes

OSHA Yes

 

Carcinogen or Potential:

Program:

 

No

Monographs:

No

No

 

 

 

 

SECTION 6 - EMERGENCY AND FIRST AID PROCEDURES

 

 

 

Eye Contact:

Flush and irrigate with water for 15 minutes while holding eyelids open.

If irritation persists, seek medical attention.

 

 

 

 

 

 

 

Skin Contact:

Wash thoroughly with soap and water. If irritation persists, seek medical attention.

 

 

 

Inhalation:

Fresh air if symptoms occur. If irritation persists, seek medical attention.

 

 

 

 

 

Ingestion:

Dilute by drinking large quantities of water.

 

 

 

 

 

 

 

SECTION 7 - SPECIAL PROTECTION INFORMATION

 

 

 

Respiratory Protection

N/A

 

 

 

 

 

 

(Specify Type):

 

 

 

 

 

 

Ventilation:

Local

N/A

 

 

Mechanical

N/A

 

Exhaust:

 

 

(General):

 

 

 

 

 

 

Protective

Rubber gloves for spill/leak

Eye

Chemical goggles recommended during

 

Gloves:

Protection:

spill/leak procedures.

 

 

 

 

Other Protective

Eye wash and safety showers are good safety practice.

 

 

Clothing or Equipment:

 

 

 

 

 

 

 

SECTION 8 - SPECIAL PRECAUTIONS AND SPILL/LEAK PROCEDURES

 

 

Precautions to be taken

Store in original container. Keep tightly closed. Keep separate from acid.

in Handling and Storage:

 

 

 

 

 

 

 

Other

See incompatibility information in Section 4.

 

 

Precautions:

 

 

 

 

 

 

 

Steps to be taken in Case

Stop leaks. Contain spills. Remove as much as possible. Place in closed container for proper disposal

 

Material is Released or Spilled:

Wash spill area with large amounts of water to remove traces and neutralize.

 

Waste Disposal

Dispose of in compliance with local, state and federal regulations.

Methods:

HAZARDOUS MATERIAL IDENTIFICATION SYSTEM

 

 

 

HAZARD INDEX

 

 

 

 

 

 

 

4 SEVERE HAZARD

0 HEALTH

 

 

 

 

 

 

3 SERIOUS HAZARD

 

 

 

 

 

 

 

2 MODERATE HAZARD

0 FLAMMABILITY

 

 

 

 

 

1 SLIGHT HAZARD

 

 

 

 

 

 

 

0 MINIMAL HAZARD

0 REACTIVITY

 

 

 

 

 

N/A = Not Applicable

NDA = No Data Available

N/E = Not Established

 

 

ANSUL and ANSULEX are registered trademarks.

 

 

 

 

 

 

 

 

 

Internet Address: http://www.ansul.com

 

 

ANSUL INCORPORATED, ONE STANTON STREET, MARINETTE, WI 54143-2542

Form No. F-90160-6

©1999 Ansul Incorporated

27

Page 29
Image 29
Bloomfield WVOC-2HFG, WVOC-2HSG operation manual Health Hazards

WVOC-2HFG, WVOC-2HSG specifications

The Bloomfield WVOC-2HSG and WVOC-2HFG models represent the cutting edge in advanced automation and control systems designed for diverse industrial applications. These systems serve as pivotal tools for optimizing processes, enhancing efficiency, and ensuring precise monitoring of various operations across numerous sectors.

One of the main features of the Bloomfield WVOC-2HSG and WVOC-2HFG is their dual functionality, which allows for simultaneous management of multiple process parameters. The WVOC-2HSG variant is tailored for high-speed data acquisition and processing, making it suitable for environments where real-time monitoring is crucial. In contrast, the WVOC-2HFG offers enhanced flexibility with its feature-rich interface and robust control capabilities, catering to applications that demand customization and adaptability.

Both models leverage advanced technologies such as Internet of Things (IoT) connectivity, enabling seamless integration with existing infrastructure. This connectivity facilitates remote monitoring and control, allowing operators to access data from anywhere, thus improving decision-making and response times. The cloud-based analytics feature further empowers users to generate insights from historical data, leading to better predictions and proactive maintenance strategies.

In terms of characteristics, the Bloomfield WVOC-2HSG and WVOC-2HFG systems come equipped with high-resolution displays and intuitive user interfaces. These interfaces are designed to minimize the learning curve for new users while providing seasoned operators with the tools needed for complex tasks. The systems also include a variety of input and output options, making them compatible with a wide array of sensors and actuators.

Durability is another significant characteristic of these models, as they are engineered to withstand challenging industrial environments. Built with rugged materials, they are resistant to dust, moisture, and extreme temperatures, ensuring reliable performance over time.

Moreover, safety features are seamlessly integrated into these systems, with built-in alarms and redundancy mechanisms designed to prevent operational failures. This commitment to safety underscores Bloomfield's dedication to providing not only performance but also peace of mind for operators.

In conclusion, the Bloomfield WVOC-2HSG and WVOC-2HFG models stand out as premier solutions in industrial automation, showcasing a blend of innovative technology, user-centric design, and enhanced durability. Whether for real-time data processing or flexible control capabilities, these systems are set to redefine standards in operational efficiency and reliability across various industries.