SECTION IX: OPERATING INSTRUCTIONS
WARNING
Water heaters are
children) with the water heater and direct vent system. UNDER NO CIRCUMSTANCES SHOULD FLAMMABLE MATERIALS, SUCH AS GASOLINE OR PAINT THINNER BE USED OR STORED IN THE VICINITY OF THIS WATER HEATER OR IN ANY LOCATION FROM WHICH FUMES COULD REACH THE WATER HEATER.
Installation or service of this water heater requires ability equivalent to that of a licensed tradesman in the field involved. Plumbing, air supply, venting, gas supply and electrical work are required.
Light the unit in accordance with the operating instructions label attached to the water heater.
Under no circumstances should the input rate exceed the input rate shown on the water heater rating plate. Over firing could result in damage or sooting of the water heater.
If the unit is exposed to the following, do not operate water heater until all corrective steps have been made by a factory authorized independent service contractor or qualified service professional.
1.Flooding to or above the level of the burner or controls
2.External firing
3.Damage
4.Firing without water
5.Sooting
NEVER OPERATE THE WATER HEATER WITHOUT FI ST BEING CERTAIN IT IS FILLED WITH WATER AND A TEMPERATURE AND PRESSURE RELIEF VALVE IS INSTALLED IN THE RELIEF VALVE OPENING OF THE WATER HEATER.
GENERAL INSTRUCTIONS
TO FILL THE WATER HEATER
1.Close the water heater drain valve by turning the knob or valve stem clockwise. If alternative water connections are provided but not used, make certain they are plugged (i.e. rear connections).
2.Open the cold water supply
3.Open several hot water faucets to allow air to escape from the system.
4.When a steady stream of water flows from the faucets, the water heater is filled. Close the faucets and check for water leaks at the water heater drain valve, combination temperature and pressure relief valve and the hot and cold water connections.
SEQUENCE OF OPERATION
1.A call for heat from thermostat
2.Blower ON
3.Pressure switch proves blower operation
4.Blower
5.Igniter
6.Main burner ON
7.Flame signal confirmed
8.Thermostat satisfied
9.Main burner OFF
10.Blower
34