normal lift operation procedures (such as loading and unloading passengers). Follow all Lift Op- eration Safety Precautions!
Remove the pump cover to gain access to the pump handle and the hand pump. See photos on page 33. To remove the pump cover, turn the wing nut located
on top 1/4 turn and lift the pump cover off. The pump handle
is inside this cover secured by two clips. Rotate the top clip to remove the pump handle.
A
Hand Pump | Release Valve | |
|
|
|
|
|
|
Note: Close backup pump release valve securely before operating electric pump.
approximate
1/16" intervals
maximum |
| Valve Tightening |
30 inch lbs |
| |
| 6SHFLÀFDWLRQ | |
minimum |
| |
| Once valve seats | |
15 inch lbs |
| (stops), tighten 15 |
| ||
seats |
| to 30 inch pounds |
| as shown. | |
(stops) |
| |
|
|
N | C |
L | |
E | O |
P | S |
O | E |
|
Release Valve
Page 34