Maintenance and Lubrication Schedule

Perform all procedures listed in previous section also

4500

Cycles

Inspect cotter pins on platform pivot pin (2)

Hydraulic Fluid (Pump) - Check level. Note: Fluid should be changed if there is visible contamination. ,QVSHFWWKHK\GUDXOLFV\VWHP F\OLQGHUKRVHVÀW- WLQJVVHDOVHWF IRUOHDNVLIÁXLGOHYHOLVORZ

,QVSHFWF\OLQGHUVÀWWLQJVDQGK\GUDXOLFFRQQHFWLRQV for wear, damage or leaks

Inspect parallel arms, bushings and pivot pins for visible wear or damage

Inspect parallel arm pivot pin mounting bolts (8)

Inspect vertical arms, handrails and pivot pins for visible wear or damage

Inspect upper/lower fold arms, rotating pivot slide arms, slide support arms and associated pivot pins, bushings, and bearings for visible wear or damage

Resecure, replace or correct as needed

Use Braun 32840-QT (Exxon® Univis HVI 26) K\GUDXOLFÁXLG do not mix with Dextron III or other K\GUDXOLFÁXLGV &KHFNÁXLGOHYHOZLWKplatform lowered fully and roll stop unfolded fully. Fill WRZLWKLQßRIWKHERWWRPRIWKHßÀOOWXEH (neck).

Tighten, repair or replace if needed.

Replace if needed.

Tighten or replace if needed.

Replace damaged parts and lubricate if needed

Replace if needed.