Maintenance and Lubrication
All listed inspection, lubrication and maintenance procedures should be repeated at “750 cycle” intervals following the scheduled “4500 Cycles” maintenance. These intervals are a general guideline for scheduling maintenance procedures and will vary according to lift use and conditions. Lifts exposed to severe conditions (weather, environment, contamination, heavy usage, etc.) may require inspection and maintenance proce-
GXUHVWREHSHUIRUPHGPRUHRIWHQWKDQVSHFLÀHG
Maintenance Indicator: The Lift Ready green LED mounted on top of the pump cover will begin to blink after every 750 cycles. The blinking LED will not affect the functions of the lift, but is a
reminder to complete necessary maintenance and lubrication. Once the lift has been serviced, fully stow the lift. Once stowed, press the UP button on the hand pendant and the Floor Level Set but- ton on the back side of the pump cover until the Lift Ready green LED stops blinking.
Discontinue lift use immediately if maintenance and lubrication procedures are not properly per- formed, or if there is any sign of wear, damage or improper operation. Contact your sales represen- tative or call The Braun Corporation at
See the Maintenance/Lubrication Schedule for recommended applications per number of cycles.
|
| 6SHFLÀHGUHFRPPHQGHG | $YDLODEOH | %UDXQ |
Lubricant | Type | Lubricant | Amount | Part No. |
LO - Light Oil | Light Penetrating Oil | LPS2, General Purpose | 11 oz. | 15807 |
(30 weight or equivalent) | Penetrating Oil | Aerosol Can |
| |
|
| |||
|
|
|
|
|
DE - | Stainless Stick | 1.68 oz. | 15806 | |
Style (tube) | Stick (tube) |
|
| |
|
|
| ||
|
|
|
|
|
LG - Light Grease | Light Grease | Lubriplate | 14 oz. | 15805 |
(Multipurpose) |
| Can |
| |
|
|
| ||
|
|
|
|
|
Page 42