IN-Limit Microswitch

The IN-Limit microswitch is located in the inboard mounting position of the platform carrier plate.

To adjust:

1.Power or manually move the ramp to the fully stowed position.

2.Remove the ramp top plate (cover).

3.With the ramp in the stowed position loosen the IN-Limit microswitch mounting screws.

4.Slide the switch body outward until resistance is felt from the switch being fully depressed.

5.Tighten the mounting screws in this position.

6.Replace the ramp top plate (cover), before oper- ating the ramp.

Manual Release Signal Microswitch

The MR-Signal microswitch is located behind the electric motor mounting plate.

To adjust:

1.Power or manually move the ramp to the fully stowed position.

2.Remove the ramp top plate (cover).

3.Disengage the manual release T-handle to so the ramp is in the manual release state.

4.Loosen the MR-Signal microswitch mounting screws.

5.Slide the switch body toward the motor mount- ing plate until resistance is felt from the switch being fully depressed.

6.Tighten the mounting screws in this position.

7.Re-engage the manual release T-handle.

8 . Replace the ramps top plate (cover), before operating the ramp.

SYSTEMS DESCRIPTIONS

IN-Limit

Microswitch

Figure M Manual backgroundManual background

Ramp in Fully-StowedPosition

(As viewed from under the carrier plate)

MR-Signal

Microswitch

Figure N Manual backgroundManual background

Ramp in Fully-StowedPosition