TROUBLESHOOTING

 

 

 

 

 

 

 

 

 

FUNCTION

SYMPTOM

 

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

2.10

2.11

Pressure mat activated

Remove object from mat.

 

Ramp Starts

 

2.12

Obstruction sensing activated

See controller diagnostic guide

 

to Deploy

Check ramp for obstructions.

 

then Stops

 

 

Check ramp for excessive debris

 

 

 

 

contamination inside cassette

2.00

 

 

 

 

2.20

 

 

 

DEPLOY

Ratcheting

2.21

Ramp OUT-Limit microswitch is out

Check adjustment or replace

OPERATION

Noise at End

 

of adjustment or defective

 

 

or during

 

 

 

 

 

 

 

Ramp

 

 

 

 

Deployment

 

 

 

 

 

 

 

 

 

2.30

2.31

Loose chain

Adjust chain

 

Excessive

2.32

Debris inside ramp cassette

Clean debris from cassette

 

Noise during

 

 

 

 

Ramp

 

 

 

 

Deployment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.10

3.11

Pressure mat activated

Remove object from mat.

 

Ramp Starts

3.12

Obstruction sensing activated

See controller diagnostic guide

 

to Stow

Check ramp for obstructions.

 

then Stops

 

 

Check ramp for excessive debris

 

 

 

 

contamination inside cassette

3.00

 

 

 

 

3.20

 

 

 

STOW

 

 

 

Ratcheting

3.21

Ramp full in limit switch defective

Check adjustment or replace

OPERATION

Noise at End

 

 

 

 

or during

 

 

 

 

Ramp Stowing

 

 

 

 

 

 

 

 

 

3.30

3.31

Lose chain

Adjust chain

 

Excessive

 

Noise while

3.32

Debris inside ramp cassette

Clean debris from cassette

 

Ramp

 

 

 

 

Stowing

 

 

 

 

 

 

 

 

Page 39

Page 41
Image 41
Braun RA500 service manual Troubleshooting, 2.00, Deploy, Operation, 3.00, Stow, Function, Symptom, Possible Cause, Remedy